Pass/Fail Test

This Test stores Pass/Fail data for a specific Defect.

Test Settings

Required Settings for this Test are:

Label

The label displayed above this Test.

You can translate this into another language (Spanish or English).

Visible

When this Test is not Visible, it will not be displayed to the data entry inspector.

Enabled

When Enabled, the data entry inspector can set or change its value.

If you use Inspection Scripts to set this Test's value, you might want to clear this checkbox so that the data entry inspector can't set or change its value.

Script ID

This is used by Inspection Scripts to identify this Test.

Required

The data entry inspector cannot Submit the Sub-Inspection until one of the buttons — Pass, Fail, or N/A —is selected.

Defect

Select the Defect that you want the data entry inspector to look for.

This Setting is required.

Sample Size

Specify the number of items that will be inspected for this Defect.

Sample Size is used to report statistics such as Yield, ratios of Defective parts to Total parts (such as Percent NCU, PPM, and NCU Sigma), and ratios of Total Defects to Total parts (such as Percent Defects, DPM, and Defect Sigma).

NCU Count on Failure

Specify the number of bad parts to store in GS if the Defect is found and the inspector Fails this Test.

NCU is used to report statistics such as Yield, Percent NCU, Percent Good, PPM, and NCU Sigma.

Test Specific Traceability

This Setting lets you set a Traceability value for only this Test on the Sub-Inspection.

If used, this Traceability value will override any other value set for this Traceability via a Traceability Test, User Setting, and so forth. For details, see Automatically setting Traceability values.

To set Test Specific Traceability:

  1. Select which Traceability to set.
  2. Set a Value for the Traceability, or leave the Value blank to let the data entry inspector enter the Value.
  3. Choose whether to make this Traceability Visible or hide it from the data entry inspector.
  4. If desired, you can add more Test Specific Traceabilities using the steps above.
  5. Select the Confirm button when finished.

Store Data

If using Inspection Scripts for this Inspection, you might want to use this Test to hold intermediate values but not store them in GS.

Your options are:

  • Store Data (the default)
  • Do Not Store Data — Use all of the GS features for this Test, and do not store its data in GS.
  • Bypass Validity and Do Not Store — Turn off all GS validation checks for this Test, and do not store its data in GS.

Note Button

This Setting affects the Note button for this Test.

It determines whether GS uses the Inspection Setting, requires the data entry inspector to enter a Note before submitting a Sub-Inspection, makes the Note optional, or hides the Note button.

When available, the data entry inspector can select this button and enter a text Note for this Test.

Alert

You can choose an Alert that will automatically send a text message or email if this Test detects a real time failure.

Show N/A

Show or hide the N/A button for this test.

Only Show if the Part Contains the Defect

If the current Part is not assigned to any Defect Categories that contain this Defect, this Test will not be displayed.

This lets you make an inspection that works for multiple Parts.

Border

Add borders to the edges of this Test.

Freeze Test

If this Test is placed on the same row as a longer Test, it will not scroll off the screen until the longer Test scrolls off the screen.

"Pass", "Fail", and "N/A" Labels

You can change the labels on the Pass, Fail, and N/A buttons.

Pass, Fail, and N/A Colors

You can change the colors for the Pass, Fail, and N/A buttons.

Translating text into another language

To translate a text field into another language (Spanish or English), select its Translate button.

Enter your translated text, then select the Save button at the top or bottom of the window.

For more information on translating text fields and changing the language displayed to the user, see Custom Translations.